Energy Performance Laboratory 100 kW
CEISLAB Energy Performance Laboratory meets the specific heating and air conditioning market needs, by testing according to the current regulations and standards.
Appliances
Our laboratories have the capability to determine following appliances’ performances, including all their multiple combination and configurations:
- Air conditioners (AC)
- Variable Refrigerant Flow (VRF)
- Liquid Chilling Packaged (LCP)
- Rooftop (RT)
- Water-to-air and air to water appliances
- Water-to-water appliances
Laboratory
The facilities allow the implementation of thermal and acoustic tests.
- Testing Chambers
Dimensions (LxWxH) 8000x1200x5500mm
Number of rooms 3
- Temperature range
Indoor rooms 15 to 35°C
Outdoor rooms -22 to 54°C
Water loop 5 to 65°C
- Relative humidity range 25 to 90% RH
- Flow Range
50 kW, AIR 1,3 to 20.000m3/h
100 kW, AIR 1,3 to 40.000m3/h
Water loop 14 to 700 kg/min
- Maximum capacity 100 kW
- Electric power
UUT voltage 166 to 480V, 1Ø & 3Ø
Grid frequency 50 & 60 Hz
Tests